| Parameter | Value | ||||
| Model | BE38 | ||||
| Weight | 155 g (incl. batteries) | ||||
| Dimensions (length x width x height) |
148 x 27 x 60 mm | ||||
| Max. diameter of conductor | approx. 25 mm | ||||
| Measuring rate | 3 per second | ||||
| Input resistance (V AC and V DC) | 9 MΩ | ||||
| Frequency range alternating current | 50/60 Hz (AAC) | ||||
| Frequency range AC voltage | 40 – 400 Hz (VAC) | ||||
| Ambient conditions | 0 °C to 40 °C with up to 75 % RH | ||||
| Storage conditions | -20 °C to 60 °C with up to 85 % RH | ||||
| Battery | 3x 3 V CR2032 button cell batteries | ||||
| Overvoltage protection | Category lll 300 V | ||||
| Type of protection | IP20 | ||||
| Transport and storage | |||||
| Measuring range | Resolution | Accuracy | Measuring range exceeded | ||
| AC voltage | |||||
| 300 V | 1 V | ± (1.2 % + 3 digits) |
– (*) | ||
| DC voltage | |||||
| 300 V | 1 V | ± (1.0 % + 2 digits) |
– (*) | ||
| Alternating current | |||||
| 20 A | 10 mA | ± (3.0 % + 5 digits) |
The figure 1 will be indicated on the display. | ||
| 200 A | 100 mA | ± (2.5 % + 5 digits) |
The figure 1 will be indicated on the display. | ||
| 400 A | 1 A | ± (2.5 % + 5 digits) |
– (*) | ||
| Resistance | |||||
| 2000 Ω | 1 Ω | ± (1.2 % + 2 digits) |
The figure 1 will be indicated on the display. | ||
| 200 kΩ | 100 Ω | ± (1.5 % + 2 digits) |
The figure 1 will be indicated on the display. | ||
Safe current measurement without interruption
The BE38 clamp meter enables contactless current measurement on live systems using the induction principle – without having to disconnect cables or switch off the system. Thanks to its compact and ergonomic design, the clamp ammeter is ideal for use in hard-to-reach places such as narrow control cabinets. It can be conveniently operated with one hand, making the BE38 a practical, safe and time-saving measuring tool for electricians, technicians and DIY users alike.




Reviews